The Trillium 120P is a compact portable sensor offering superior broadband performance over a wide temperature range. Instrument self-noise is within 4 dB of the NLNM (New Low Noise Model) at 100 seconds and below the NLNM up to 10Hz.  The very low self-noise of the Trillium 120P makes it ideal for local, regional and teleseismic studies in both observatory and portable applications. Portable network users will appreciate the low power consumption and reliable operation over a temperature range of ±45ºC without re-centering.

This instrument incorporates the same symmetric tri-axial design and suspension system as the highly successful Trillium 40. The design employs fewer parts than traditional sensors and offers improved temperature stability. The robustness and reliability of the mechanical suspension is well proven. With more than 500 Trillium 40 units operating in the field, there have been no mechanical failures.

As with all Trillium sensors, the 120P does not have a mass lock, instead using a field proven suspension system capable of withstanding the rigors of field handling and transportation. During deployment the sensor requires only manual leveling before operation.

Trillium 120P Technical Specifications

 TECHNOLOGY                                                               
 Topology Symmetric triaxial
 Feedback Force balance with capacitive transducer
 Mass centering
Operates over full temperature range without manual re-centering;
Manual centering control included 
 LevelingIntegrated bubble level; Adjustable locking leveling feet 
 Alignment
Vertical scribe marks for N/S; Precision N/S guide in top of cover for straight-edge,
line or laser level; Precision holes for 5/16" alignment rod for E/W  
  
 PERFORMANCE 
 Self-noise 4 dB above the NLNM at 100 seconds and below the NLNM up to 10 Hz
 Sensitivity1201 V*s/m ±0.5%
 Bandwidth-3 dB points at 120s and 145 Hz 
 Transfer function
Lower corner poles within ±0.5% of nominal provided; High frequency poles
and zeros within ±5% of nominal provided 
 Clip level> 15 mm/s up to 1.5 Hz 
 Temperature±45°C without re-centering
  
 INTERFACE 
 Connector19-pin MIL-C-26482, mounted in base 
 Velocity output40 V peak-to-peak differential; Selectable XYZ or UVW mode 
 Mass positionThree independent voltage outputs 
 Calibration input
Single voltage input with one active high control signal per channel; Calibration
in XYZ or UVW, selectable via control lines
 Serial portFor retrieval of sensor response information and instrument control 
  
 POWER 
 Supply voltage9 to 36 volts DC isolated input 
 Power consumption650 mW typical at 15 V input 
 Protection
Reverse-voltage protection; Auto-resettable over-current protection
(No fuse to replace)
  
 PHYSICAL 
 Diameter21.0 cm 
 Height20.9 cm to 21.8 cm depending on leveling feet extension 
 Weight7.2 Kg 
 HandlingDetachable lifting handle included 
  
 ENVIRONMENTAL 
 Operating temp.-20°C to +50°C
 Humidity0 to 100% 
 Shock
20g half sine, 5 ms without damage, 6 axes;
No mass lock required for transport 
 PackagingRated to IP68 and NEMA6P for outdoor use 