A compact portable sensor offering superior broadband performance over a wide temperature range with very low self noise. This low self-noise makes the Trillium 120P/PA ideal for local, regional and tele-seismic studies in both observatory and portable applications. Portable network users will appreciate the low power consumption and reliable operation over a temperature range of ±45ºC without re-centering.
The Trillium PA offers the added benefit of fast "one touch" motorized mass centering. Motorized mass centering simplifies seismometer installation and provides the option of remotely re-centering the masses via a telemetry connection.

Very broadband performance from a portable, low -power seismometer
Wide ranging temperature operations (+/-45°C) without re-centering
Switchable XYZ/UVW output to provide independent calibration of sensor axes
Simple operation with no mass lock to employ
Trillium PA offers the added benefit of motorized mass centering for rapid deployment and remote adjustment
TECHNOLOGY |
|
| Topology | Symmetric triaxial |
| Feedback | Force balance with capacitive transducer |
| Mass Centering | Automatic motorized re-centering, can be remotely initiated |
| Leveling | Integrated bubble level; Adjustable locking leveling feet |
| Alignment |
Vertical scribe marks for (N and S); Precision guide in cover for straight-edge, line or laser level; Holes for 5/16" alignment (E and W)
|
PERFORMANCE |
|
| Self-noise | Below the NLNM 35 s up to 10 Hz |
| Sensitivity | 1200 V-s/m ±0.5% precision, Contact factory for other options |
| Bandwidth | -3 dB points at 120s and 145 Hz |
| Clip Level | > 15 mm/s up to 1.5 Hz |
|
Temperature |
±45°C without re-centering |
INTERFACE |
|
| Connector | 19-pin MIL-C-28642 |
| Velocity Output | 40 V peak-to-peak differential; Selectable XYZ or UVW mode |
| Mass Position Output | Three independent voltage outputs |
| Calibration Input | Single voltage input with one active high control signal per channel; Calibration in XYZ or UVW |
| Serial Port |
For enhanced instrument control and status:
Mass center, UVW/XYZ mode, short/long period mode, firmware updates Temperature, mass position, instrument status, serial number
|
POWER |
|
| Supply Voltage | 9 to 36 volts DC isolated input |
| Power Consumption | 620 mW typical at 15 V input |
| Protection |
Reverse-voltage protection; Auto-resettable over-current protection
(No fuse to replace)
|
PHYSICAL |
|
| Diameter | 21.0 cm |
| Height | 21.4 cm ±0.5 cm depending on leveling feet extension |
| Weight | 7.5 Kg |
| Handling | Detachable carrying handle on lid |
ENVIRONMENTAL |
|
| Operating temp | -20°C to +50°C |
| Humidity | 0 to 100% |
| Shock |
20g half sine, 5 ms without damage, 6 axis; No mass lock required for transport |
| Rugged | Rated to IP68 and NEMA6P for outdoor use |