The Trillium Compact Exploration has been designed for rapid and repeated deployments and is specifically tuned for frequencies of 1Hz to 10Hz. It features an ultra-low noise floor and 20s corner frequency.
Areas of application include
TECHNOLOGY |
|
| Topology | Symmetric tri-axial |
| Feedback | Force balance with capacitive transducer |
| Mass Centering | Not required |
| Levelling | No levelling within 10° vertical |
| Alignment |
Vertical scribe marks for N/S |
PERFORMANCE |
|
| Self-noise | See Performance |
| Sensitivity | 750 V-s/m nominal ± 1% precision |
| Off-axis Sensitivity | ± 0.5% |
| Bandwidth | -3db points at 20s and 100 Hz |
| Transfer Function |
Lower corner poles within ±1% of nominal provided High-frequency poles within ±5% of nominal provided No peak in response at high frequency |
| Clip Level | 26 mm/s from 0.1 Hz to 10 Hz |
| Operational Tilt Range | ±10° |
|
Parasitic Resonances |
None below 200 Hz |
INTERFACE |
|
| Connector | 14-pin, shell size 12, MIL-C-26482 Series I, top mounted |
| Velocity Output | 2.5 or 5 V peak-to-peak differential |
| Mass Position | Selectable XYZ or UVW mode |
| Output | Single voltage output representing maximum mass position |
| Calibration Input |
Single voltage input and one active high control signal to enable all 3 channels. Remote calibration in XYZ or UVW mode Independent channel selection by serial port |
DIGITAL COMMAND AND CONTROL INTERFACE |
|
| Digital Interface |
RS-232 compatible serial IP (SLIP)
Onboard web server standard HTTP |
| Digital Commands |
XYZ, UVW mode switching Calibration channel selection (off, enable all, u, v, or w) Short/long period mode Firmware updates State-of-health request |
| Digital Data Outputs |
Independent mass position values Instrument temperature Factory sensitivity Instrument serial number and firmware revision |
POWER |
|
| Supply Voltage | 9-36 V DC isolated input |
| Power Consumption |
165 mW typical when level Up to 250 mW when tilted |
| Protection |
Reverse-voltage and over-voltage protected Self-resetting over-current protection |