The Trillium Compact Exploration is specifically tuned for frequencies below 10Hz: ideal for low frequency seismic surveys designed to identify hydrocarbon reserves or the continuous low frequency monitoring of hydro-frac operations. The Trillium Compact Exploration features an ultra-low noise floor and 20s corner frequency.
The Trillium Compact Exploration has been designed for rapid and repeated deployments. Ease of use features include:
TECHNOLOGY |
|
| Topology | Symmetric tri-axial |
| Feedback | Force balance with capacitive transducer |
| Mass Centering | Not Required |
| Alignment | Vertical scribe marks for N and S, holes for 5/16" alignment, rod for E and W |
PERFORMANCE |
|
| Self-noise | See graph |
| Off-axis Sensitivity | ± 0.5% |
| Bandwidth | -3db points at 20s and 100 Hz |
| Transfer Function |
Lower corner poles within ±0.5% of nominal provided High-frequency poles within ±5% of nominal provided No peak in response at high frequency |
| Clip Level | 26 mm/s from 0.1 Hz to 10 Hz |
| Operational Tilt Range | ±10° |
|
Parasitic Resonances |
None below 200 Hz |
INTERFACE |
|
| Connector | 14-pin, shell size 12, MIL-C-26482 Series I, top mounted |
| Velocity Output | 40 V peak-to-peak differential Selectable XYZ or UVW mode |
| Mass Position Output | Single voltage output representing max mass position 3-channel mass positions available through serial port |
| Calibration Input |
Single voltage input and one active high control signal to enable all 3 channels. Remote calibration in XYZ or UVW mode Independent channel selection by serial port |
DIGITAL COMMAND AND CONTROL INTERFACE |
|
| Digital Interface |
RS-232 compatible serial IP (SLIP)
Onboard web server standard HTTP |
| Digital Commands |
XYZ, UVW mode switching Calibration channel selection (off, enable all, u, v, or w) Short/long period mode Firmware updates State-of-health request |
| Digital Data Outputs |
Independent mass position values Instrument temperature Factory sensitivity User calibration data (poles and zeros) Instrument serial number and firmware revision |
POWER |
|
| Supply Voltage | 9-36 V DC isolated input |
| Power Consumption | < 160 mW typical |
| Protection | Reverse-voltage and over-voltage protected Self-resetting over-current protection |